home *** CD-ROM | disk | FTP | other *** search
/ Amiga Format CD 36 / Amiga Format CD36 (1999-01-22)(Future Publishing)(GB)[!][issue 1999-02].iso / -seriously_amiga- / hardware / scantek / readme < prev    next >
Text File  |  1998-12-12  |  13KB  |  407 lines

  1.  
  2.                         ScanTek 4.3
  3.  
  4.                     A scanner driver for
  5.                Microtek, Highscreen and Mustek
  6.                       Flatbed Scanner
  7.  
  8.  
  9.           © Copyright 1995/96/97/98 Waldemar Zöhner
  10.     email: scantek@gmx.de, wzoehner@gmx.de oder wzoehner@odn.de
  11.        http://www.users.odn.de/~odn05111/scantek.html
  12.  
  13.                   Get It, Feel It, Love It
  14.  
  15.  
  16.  Overview
  17. ----------
  18.  
  19.  The ScanTek scanner driver has the following features:
  20.  
  21.  1. Support of the following SCSI Microtek scanner models:
  22.         MICROTEK IISP, MICROTEK II, HIGHSCREEN Flatbed Color IIs,
  23.         ScanMaker E3, ScanMaker 35t, ScanMaker E6,
  24.         Highscreen PerfectScan, older Highscreen HighScan
  25.  
  26.         Microtek E3PLUS, V300, 330, 630 and new Highscreen HighScan
  27.  
  28.            This new scanner model can be used in black&white, grey scale
  29.            and color scanning.
  30.            The download of color lookup tables (gamma curves) is now
  31.            supported.
  32.            Color scan images can contain a shifted segment, if the image
  33.            data is written to a harddisk on the same SCSI host adapter.
  34.            The image data should be written to a harddisk on another SCSI
  35.            host adapter or to a IDE harddisk.
  36.  
  37.  
  38.     Support of the following SCSI Mustek Paragon scanner models:
  39.         Three Pass Scanners:
  40.         Paragon 6000CX, 8000CX (not tested), 12000CX all should work
  41.  
  42.         One or Single Pass Scanners:
  43.         Paragon 6000SP, 8000SP, 12000SP (now supported) all should work
  44.         Paragon 6000CZ, 8000CZ (not tested)
  45.  
  46.         Paragon 600IISP, 800IISP
  47.  
  48.  
  49.     The following scanner models are in the development phase:
  50.         Microtek ScanMaker 636, 336 and x6           
  51.           Scanned images of this models may contain strong color failures.
  52.           After the reception of the new Microtek programming documentation
  53.           this filaure can be resolved. A fast solution is possible.
  54.  
  55.  
  56.     The following scanner models are recognized but not fully supported: 
  57.         Mustek ScanExpress 12000SP
  58.         Mustek Paragon 1200IIISP (caution: III -> version 3)
  59.            Color scanning is only successfull at resolutions of 150, 300,
  60.            600 and 1200 dpi.
  61.            Grey scale scanning is possible.
  62.            If the image to be scanned exceeds the scan buffer size than
  63.            the image is corrupt. This effect is independent from the
  64.            scan mode.
  65.            The scanning quality is also (!) dependent from the used
  66.            SCSI host adapter.
  67.            The ScanExpress or Paragon 12000IIISP scanner models are
  68.            not recommended for ScanTek.
  69.            At least until sometimes in the future the corresponding
  70.            Mustek SCSI programming documentation for these new models
  71.            is available. I think this might be a Millenium projekt.
  72.  
  73.  
  74.     The following scanner models are not supported by now: 
  75.         All remaining Mustek ScanExpress and Paragon IIISP models.
  76.  
  77.  
  78.     The following scanner models are not supported:
  79.         Canon, Epson, HP, Umax and any parallelport scanner.
  80.  
  81.  
  82.     Attention: In recent times Mustek has changed the scanner firmware.
  83.                I urge you to test Mustek scanners with your Amiga
  84.                configuration before buying it.
  85.  
  86.                Mustek scanners have a critical SCSI interface. It
  87.                was reported to me that these scanners may not work
  88.                with the A2091 and A3000(T) internal SCSI interface.
  89.                It is possible that these scanners do not work with
  90.                other SCSI host adapters, either.
  91.                But the Mustek 6000CX and Paragon MFS-12000SP work in
  92.                combination with an Oktagon SCSI host adapter.
  93.                Be sure to disable reselection for Mustek scanners
  94.                on your SCSI host adapter. Otherwise your system may
  95.                not boot.
  96.  
  97.  2. Support of black/white, built-in halftone (dither), one-pass-color-scan,
  98.     three pass color scan, grey, red, green and blue scan.
  99.  
  100.  3. Individual setting of resolution, scanning frame, contrast, shadow,
  101.     midtone, highlight, exposure time and scanning speed for download to the
  102.     scanner.
  103.  
  104.  4. Download of a color look up table (gamma correction table ) to the scanner
  105.     supported.
  106.  
  107.  5. Scanning to IFF File of 1, 8 or 24 bit color depth. The maximum size of
  108.     the scanned image is independent from the RAM size. After the scanning
  109.     process it is possible to start an external program.
  110.  
  111.  6. GUI for preview and configuration of the driver. You need Kickstart 2.04
  112.     but Kickstart 3.0 is recommended.
  113.  
  114.  7. Sizeable preview window in black/white or grey scale. Color preview
  115.     on Cybergraphix screens (15, 16 or 24 bit necessary).
  116.     There are much more skilled programs to view and manipulate the scanned
  117.     images in color. (A tool like ADPRO, IMAGE FX or so is needed, if you
  118.     want to do sophisticated postproduction)
  119.  
  120.  8. ARexx support
  121.  
  122.  9. Screenmode requester to define custom screen for working. The actual public
  123.     screen is supported as well
  124.  
  125.  10. Configurable SCSI device and SCSI ID. The driver supports only SCSI
  126.      connectable scanners.
  127.  
  128.  11. The driver is tested with the following SCSI drivers: oktagon.device and
  129.      gvpscsi.device V4.5.
  130.  
  131.  12. ScanTek is written using SAS C 6.58.
  132.  
  133.  13. ScanTek is SHAREWARE.
  134.  
  135.  14. The non registered version of ScanTek is a full working version, but all
  136.      scanned images have black lines to motivate you to register.
  137.      Additionally the maximum size of the preview is restricted.
  138.  
  139.  
  140.  History
  141. ---------
  142.  
  143.  V4.3  6 December 1998
  144.  
  145.    - Support of the transparency adapter and control of the scanning and
  146.      transparency medium lamp for Microtek 63x, 33x and compatible
  147.      Highscreen HighScan scanner models
  148.  
  149.  
  150.  V4.2  9 September 1998
  151.  
  152.    - Locale catalogs now updated correctly
  153.  
  154.    - No color failures if the LookUp tables are deactivted for
  155.      Microtek 630, 330 and new Highscan II models
  156.  
  157.  
  158.  V4.1 29 August 1998
  159.  
  160.    - Full support for Microtek 630, 330 and new Highscan II models
  161.      - Color LookUp tables now supported
  162.      - Faster preview for new generation of ScanMaker scanners
  163.  
  164.    - ScanTek support homepage has been moved to
  165.        http://www.users.odn.de/~odn05111/scantek.html
  166.  
  167.    - Enhanced screen mode handling on program startup
  168.  
  169.  
  170.  V4.0 19 June 1998
  171.  
  172.    - Localization of ScanTek. Supported locales: english, deutsch, dansk
  173.  
  174.    - New email address: scantek@gmx.de, wzoehner@gmx.de
  175.  
  176.  
  177.  V3.11 24 May 1998
  178.  
  179.    - Support of the new Highscreen HighScan II (Microtek) and
  180.      the new version of the Microtek E3Plus
  181.  
  182.  
  183.  V3.10 17 April 1998
  184.  
  185.    - First attempt to support the new Microtek 330 scanner model.
  186.      The scanning speed depends in a large degree on the SCSI host adapter.
  187.      This scanner model may lead to hang ups of the SCSI bus (computer
  188.      system) on critical SCSI devices.
  189.  
  190.  
  191.  V3.9  15 March 1998
  192.  
  193.    - Better support for Mustek ScanExpress 12000SP and the identical
  194.      international Mustek Paragon 1200 III SP.
  195.      This scanner model is not recommended for ScanTek.
  196.        Preview works now also on small preview windows.
  197.        Color scanning is only successful at resolutions of 150, 300,
  198.        600 and 1200 dpi.
  199.        Only small scanning images are successful. The automatic segment
  200.        scanning is not possible on this scanner model.
  201.  
  202.    - The new Microtek model ScanMaker E3PLUS is in the testing phase.
  203.      (see Overview for details)
  204.    
  205.    - Microtek V300, Microtek 330, Microtek 630
  206.        These scanner models are due to the documentation related to           
  207.        the Microtek E3PLUS. They should work in an equivalent way.
  208.  
  209.  
  210.  V3.8  23 February 1997
  211.  
  212.    - Bugfix of Mustek color scan process (Scrambled image data in
  213.      segment scanning)
  214.  
  215.    - Support of Transparency Adapter (Slide Kit Unit) enhanced
  216.  
  217.    - First attempt to support the new european Mustek
  218.      ScanExpress 12000SP and international Mustek Paragon 1200 III SP.
  219.      These scanners are assumed to be identical.
  220.      Due to missing Mustek programming documentation for the new firmware
  221.      there is only a limited support of these scanner models:
  222.        ... Gray scale scanning is supported.
  223.        ... Color scanning is incorrect and is therefore unusable
  224.      These scanner models are not recommended for the use with ScanTek.
  225.      If there will be a Mustek programming documentation some time in the
  226.      future than a second attempt for the support will be made.
  227.  
  228.  
  229.  V3.7  30 December 1997
  230.  
  231.    - Detection of Mustek scanners enhanced
  232.      Erkennung von Mustek Scannern weiterentwickelt
  233.  
  234.    - German Documentation
  235.      Deutsche Anleitung
  236.  
  237.  
  238.  V3.6  21 December 1997
  239.  
  240.    - The Mustek MFS-12000SP is now supported
  241.    - Rework of ASL requester handling
  242.    - PROGDIR: usage reduced
  243.  
  244.  
  245.  V3.5  4 December 1997
  246.  
  247.    - Rework of window activation procedures
  248.    - Rework of font sentivity
  249.    - PROGDIR: usage reduced
  250.    - Support of multiple SCSI host adapters in one system
  251.  
  252.  
  253.  V3.4  21 October 1997
  254.  
  255.    - Support of Transparency Adapter (Slide Kit Unit)
  256.    - Prevent system lockup during startup on Dataflyer SCSI+ host
  257.      adapter
  258.  
  259.  
  260.  V3.3   1 August 1997
  261.  
  262.    - Detection of ScanMaker35t+ introduced 
  263.    - Faster preview scanning process on some scanner models
  264.    - "Accurate Coordinates" support for ScanMaker E6 and compatible
  265.  
  266.  
  267.  V3.2   8 June 1997
  268.  
  269.    - Workaround for surfsquirrel.device to avoid SCSI bus hangup
  270.    - AREXX scripts: Load scanned pictures into 
  271.                     ImageFX:   ST2ImageFX.strx
  272.                     ArtEffect: ST2ArtEffect.strx
  273.  
  274.  
  275.  V3.1  19 May 1997
  276.  
  277.    - Recognition of Highscreen PerfectScan (600dpi) introduced
  278.    - Recognition of Highscreen RealScan (300dpi) introduced
  279.    - Activation of newly opened windows works now correct
  280.  
  281.  
  282.  V3.0   16 Apr. 1997
  283.  
  284.    - AREXX support
  285.    - XBMI-chunk introduced to store DPI (dots per inch) information in
  286.      IFF File
  287.    - Handling of Microtek ScanMaker E6 enhanced
  288.    - Bugfixes: "Exposure Time" and "Contrast" parameters for Microtek
  289.                and some Mustek scanner models are now correct.
  290.                This bug could lead to images that where to light.
  291.                Grey preview of color image now work with all specified
  292.                settings.
  293.  
  294.  
  295.  V2.10 26 Mar. 1997
  296.  
  297.    - Full size preview on 400 dpi Mustek scanners adjustable
  298.  
  299.  
  300.  V2.9   9 Feb. 1997
  301.  
  302.    - Look Up Table Window redesigned to ensure font sensitivity
  303.  
  304.  
  305.  V2.8  11 Jan. 1997
  306.  
  307.    - New icons for ScanTek
  308.    - Recognition and handling of new Mustek scanners enhanced
  309.    - Minior bug fixes
  310.    - Introduction of the ScanTek Support WebSite
  311.  
  312.  
  313.  V2.7  6 Dec. 1996
  314.  
  315.    - Recognition and handling of new Mustek scanners enhanced
  316.    - Recognition of Microtek ScanMaker E6 adapted
  317.  
  318.  
  319.  V2.6  30 Oct. 1996
  320.  
  321.    - Full support of Mustek one pass scanners
  322.    - Recognition of Mustek scanners enhanced
  323.  
  324.  
  325.  V2.5  5 Oct. 1996
  326.  
  327.    - Workaround to handle strange color mode behaviour of Mustek
  328.      one pass scanners
  329.    - Reverse scanning in black and white mode introduced
  330.  
  331.  
  332.  V2.4 10 Sept. 1996
  333.  
  334.    - Support of Mustek SCSI one pass color scanners in color mode and
  335.      parameter ranges.
  336.    - ScanTek can now open its GUI windows on the actual public screen.
  337.  
  338.  
  339.  V2.3  6 Sept. 1996
  340.  
  341.    - Color Preview on Cybergraphix screens in true color mode
  342.      (15, 16 or 24 bit) for onepass flatbed scanners
  343.    - Grey/Red/Green/Blue Preview on Cybergraphix screens in true color mode
  344.      (15, 16 or 24 bit) for threepass and onepass flatbed scanners
  345.    - Change and recall of predefined resolution values
  346.  
  347.  
  348.  V2.2 26 July 1996
  349.  
  350.    - Enhanced support for Mustek scanners
  351.      "Exposure Time" and "Contrast" parameters are now correct
  352.    - Gamma value "All" now works on threepass scanner
  353.    - Alternative Black/White scanning mode
  354.  
  355.  
  356.  V2.1  5 July 1996
  357.  
  358.    - Preview now fully supported for Mustek 6000CX
  359.    - Special adaption for Mustek 6000CX to use 8.5 * 14 inch scanning frame
  360.  
  361.  
  362.  V2.0  30 Apr. 1996
  363.  
  364.    - Preview in color mode with proper options values
  365.    - Use of expanded Contrast and Exposure Time selections on certain scanners
  366.    - X and Y Aspect Ratio in color images is correct now
  367.    - ScanMaker E3 does not support undocumentated red, gree and blue scanning
  368.    - Lookup Table command supported (Gamma Correction on certain scanner
  369.      possible)
  370.    - Scanning Frame Setting is now more intuitive
  371.    - Reverse image scanning supported (only on certain scanners possible)
  372.    - Accurate scanning supported. Scanning frame is now more precise.
  373.  
  374.  
  375.  V1.3  25 Feb. 1996
  376.  
  377.    - Detection of new ScanMaker E3 Flatbed scanner implemented
  378.    - Special adaption for E3 to use 8.5 * 13.5 inch scanning frame
  379.      (due to E3 inquiry data the max frame size is 8.5 * 11.69 inch)
  380.    - No start of the external program, if the scanning process is aborted
  381.    - Higher dpi rates for ScanMaker 35t (slide scanner) possible
  382.      Preview image should look better now.
  383.    - "Main Control" window and gadgets modified
  384.    - Debug filename "ScanTek.log" can be overriden through CLI or Tooltype
  385.  
  386.  
  387.  V1.2   3 Jan. 1996
  388.  
  389.    - Debug output data revised and enhanced
  390.    - Max Frame Setting setting introduced
  391.    - Start of external program possible
  392.    - Window positions are remembered and saved
  393.    - Configuration file enhanced
  394.  
  395.  
  396.  V1.1  17 Dec. 1995
  397.  
  398.    - detection of Microtek scanner via SCSI inquiry enhanced
  399.    - stepping of resolution slider adapted to expanded base resolution
  400.    - calculation of scanning frame size data modified
  401.  
  402.  
  403.  V1.0  30 Nov. 1995
  404.  
  405.    - first public release
  406.  
  407.